Each firmware has different requirements for saving PID values. Consult your firmware's documentation to determine the correct method.

As the tuning runs, the printer will calculate values for Kp, Ki, and Kd. When it is done, take the last three values provided and set these using the M301 command. For this example:

M301 P29.31 I3.88 D55.42

In the case of multiple extruders, these settings will be applied to all of them.

For the bed, use M304 instead.

You can also save the values through the EEPROM settings in MatterControl.